Details for TPI Wall/Ceiling Inlet Valves

Engineered using a specialized polyurethane formula, TPI ventilation air inlets boast exceptional insulation properties, rendering them exceptionally suitable for even the harshest weather.

TPI Wall Inlet Valves

PART # DESCRIPTION CFM @ 0.05 SP CFM @ 0.10 SP  R.S.O. 
E65-3018VFG-C 1800 VFG-C INLET (central arm) 1,184 1,642  21-3/4″W x 16-1/2″H 
E65-3030VFG-C 3000 VFG-C INLET (central arm) 1,908 2,693  34-1/2″W x 15-1/4″H 
E65-3030FG-C 3000 FG-C (reverse flange) 1,908 2,693  34-1/2″W x 15-1/2″H 

WIND HOODS

PART # DESCRIPTION  INSIDE FRAMING DIMENSION 
E65-31145 TPI-950 WIND HOOD 145  30-1/2″W x 23-3/4″H x 9-3/4″D 
E65-3130 TPI-951 WIND HOOD 3000  41″W x 28″H x 14″D 
E65-3118 TPI-954 WIND HOOD 1800  29-1/4″W x 28-5/8″H x 15-3/4″ D 
OPTIONAL
E52-6782 LIGHT TRAP FOR WH1800 WIND HOOD FRAME SIZE 26″ x 15-1/2″ UNASSEMBLED
E52-6783 LIGHT TRAP FOR WH3000 WIND HOOD FRAME SIZE 37″ x 13-5/8″ UNASSEMBLED
E65-32916Z TPI-916Z LIGHT TRAP BRACKET
REQUIRED TO SUPPORT LIGHT TRAP IN WH1800 WIND HOOD
E65-32918Z TPI-918Z LIGHT TRAP BRACKET
REQUIRED TO SUPPORT LIGHT TRAP IN WH3000  WIND HOOD

TPI Modular Tunnel Wall Inlet Valves

PART # DESCRIPTION  CFM @ .07 S.P.   R.S.O. 
E65-3060VFG-2 MODEL 6000 VFG-2 (side arms) *10,300  59-3/4″W x 32″H 
E65-3060VFG-3 MODEL 6000 VFG-3 (side arms) *15,450  59-3/4″W x 48″H 

*UNITS CAN BE STACKED TO GIVE MORE CFM
Example: Stack 6000VFG-2 and 6000VFG-3 results in 25,750 CFM.
Stack 2 6000VFG-3 results in 30,900 CFM. This also gives the option of two stage opening.

A standard actuator can operate multiple sets of inlets. Call for details.

OPERATING HARDWARE REQUIRED

Operating kits include 2 rods and hardware for the inlet arm.

PART # DESCRIPTION
E65-32307 TPI-307 CLOSING LATCH (OPTIONAL) 2 PER #6000
E65-32519 TPI-519 MAIN CABLE SUPPORT 2 REQUIRED
E65-32208A TPI-208A OPENING KIT (6000VFG2) 1 REQ’D PER INLET
E65-32209A TPI-209A OPENING KIT (6000VFG3) 1 REQ’D PER INLET
E65-32415 TPI-415 WALL BRACKET (6000VFG) 2 REQUIRED
E65-32107 TPI-107 WIRE BIRD MESH (6000VFG) 1 PER SECTION
E57-8320 3-1/2″ PULLEY 1 PER TPI-415

It is advisable, in most cases, to build a wind hood on site equal to or larger than the R.S.O of the inlets.

TPI Ceiling Inlet Valves

PART # DESCRIPTION  CFM @ 0.05 S.P.  CFM @ 0.10 S.P.  R.S.O. 
E65-300120P-3 MODEL 120-P3 CEILING INLET 918 CFM @ 0.08 S.P.   9-3/4″W x 25-1/2″L
E65-0294 INSULATION STOP 120-P3     9-1/2″ x 25-1/4″ x 16″H
E65-300160P-3  ** MODEL 160P-3 CEILING INLET 1,053 1,478 20-1/4″W x 18-1/2″L
E65-0292 INSULATION STOP 160P-3     19-3/4″W x 18″ x 16″H
E65-300160P-3D** MODEL 160P-3D CEILING INLET 2,106 2,955 20-1/4″W x 39-1/2″L
E65-0293 INSULATION STOP 160P-3D     19-3/4″W x 39-1/4″ x 16″H

** C/W Front seal

MODEL 220-P CORRIDOR INLET

Air inlet valve designed for installation in the ceiling. This execution however, is especially suitable for the installation above corridors. The vertical air stream from the inlets guides the relative cold incoming air to the corridor, preventing it from dropping directly on the animals.

PART # DESCRIPTION  CFM  R.S.O.
E65-300220-P CORRIDOR INLET  1945 @.08SP  12.50″W x 35″L

ACCESSORIES

PART # DESCRIPTION
E65-32280 2PC BLACK PLASTIC CONTROL ARM
E65-32280Z 1PC BLACK PLASTIC CONTROL ARM WITHOUT BASE
(ST.ST. HARDWARE EXTRA)

OPTIONAL

E65-32519 TPI-519 MAIN CABLE SUPPORT
E65-32414 TPI-414 STAINLESS CENTER PULLEY/SUPPORT (OPTIONAL)
E65-32111 TPI-111 WIRE MESH (1800)
E65-32103 TPI-103 WIRE MESH (3000) 
E65-0667 NYLON INLET BLOCK
E65-32421 TPI-421 DELUXE CENTRE NYLON PULLEY 
E65-0290 WALL LINER “EXTENSION” (POLYPROPYLENE) FOR 1800VFG-C
21-1/4″ x 16-1/4″ X 9″ DEEP 
E65-0291 WALL LINER “EXTENSION” (POLYPROPYLENE) FOR 3000VFG-C
34-1/4″ x 15″ X 9″ DEEP 
E65-32307 TPI-307 CLOSING LATCH (recommended)

TPI Omniflux 'Slide' Inlet

PART # DESCRIPTION  CFM @ 0.05 S.P.  CFM @ 0.10 S.P.  R.S.O. 
E65-3040OMFX OMNIFLUX SLIDE INLET 2,106  2,922 30.5″W x 19″H
  COMPLETE WITH MESH, CONNECTION SET AND PULLEY UNIT WITH INTEGRATED CLOSING LATCH

Optional

PART # DESCRIPTION
E65-32117 TPI-117 WIRE MESH
E65-3140 TPI-952 WIND HOOD 4000 (USE WITH LIGHT TRAP)
E65-3130 TPI-951 WIND HOOD 3000 (USE WITHOUT LIGHT TRAP) 
E52-6784 LIGHT TRAP FOR WH4000 WIND HOOD
(FRAME SIZE 34″ x 25.50″ UNASSEMBLED)
E65-32919Z TPI-919Z LIGHT TRAP BRACKET
(REQUIRED TO SUPPORT LIGHT TRAP IN WH4000 WIND HOOD)

TPI Ventum Wall Inlet

PART # DESCRIPTION CFM @ 0.05 S.P. CFM @ 0.10 S.P.  R.S.O. 
E65-3050VNTMY VENTUM WALL INLET (13″H X 44″W) 2,290 3,218 13.5″ X 44.5″ W
E65-32204C CENTRE ARM CONNECTION SET (CABLE CLAMP & CORD)
(ORDER SEPARATELY)

Optional

PART # DESCRIPTION
E65-32519 TPI-519 MAIN CABLE SUPPORT
E65-32423 TPI-423 DELUXE PULLEY W/CLOSING LATCH
E65-32955 TPI-955 WIND HOOD FOR AERON/VENTUM (OPTIONAL)
E65-0667 NYLON INLET BLOCK
E65-32119 TPI-119 WIRE MESH

TPI Aeron Wall Inlet

PART # DESCRIPTION CFM @ 0.05 S.P. CFM @ 0.10 S.P.  R.S.O. 
E65-300AERON AERON WALL INLET 2,040 2,890 40-1/4″W x 16-1/2″H
E65-32204C CABLE CLAMP & CORD (1 PER INLET REQ’D)      

Optional

PART # DESCRIPTION
E65-32423 TPI-423 DELUXE PULLEY W/CLOSING LATCH
E65-32120 TPI-120 WIRE MESH 
E65-32955 TPI-955 WIND HOOD FOR AERON/VENTUM 

TPI Vuela Wall Inlet

PART # DESCRIPTION  R.S.O. 
E65-300VUELA VUELA WALL INLET 26.125″W X 11.25″H

TPI Ventum Tunnel Inlet

PART # DESCRIPTION CFM @ 0.08 S.P.
E65-3050VNT-5 VENTUM-5 TUNNEL INLET 14,420
E65-3050VNT-B VENTUM BOTTOM (NO TOP FLANGE) 2,884
E65-3050VNT-M VENTUM MIDDLE (NO TOP/BOTTOM FLANGE) 2,884
E65-3050VNT-T VENTUM TOP (NO BOTTOM FLANGE) 2,884
E65-3050VNT-4 VENTUM-4 TUNNEL INLET 11,536
E65-3050VNT-3 VENTUM-3 TUNNEL INLET 8,652
E65-3050VNT-2 VENTUM-2 TUNNEL INLET 5,768

VENTUM CONNECTION SETS AND HARDWARE

PART # DESCRIPTION
E65-32222 TPI-222 CONN ST. VENTUM-2 UNIT
E65-32223 TPI-223 CONN ST. VENTUM-3 UNIT
E65-32224 TPI-224 CONN ST. VENTUM-4 UNIT
E65-32225 TPI-225 CONN ST. VENTUM-5 UNIT
E65-32519 TPI-519 MAIN CABLE SUPPORT