Details for J&D Permanent Magnet Direct Drive Panel Fans
SPECIAL ORDER ITEM- Contact our sales team for Dealer Quotes and Delivery Options.
J&D Manufacturing- Dairy Solutions
Permanent Magnet Direct Drive Panel Fans
●Save time and money with no belts to change, pulleys to maintain and no lubrication required.
●Totally enclosed IP65 rated high efficiency motor.
●Internal motor drive provides soft starts. Allows for precise and uniform speed control.
●Increases efficiency when run at low speeds.
●Heavy-Duty X-Frame comprised of 10-gauge, G90 galvanized steel.
●Superior strength and rigidity of the frame minimizes vibration.
Available in 50″, 55″ & 60″
3 Year Warranty on ENTIRE fan!
Single Phase
PART # |
Size |
HP |
VOLTS |
AMPS |
Phase |
Spd |
@ 0.10” SP CFM |
CFM/Watt |
Drive |
Prop |
EVPX50P3PM221A |
50″ |
2.2kW |
190-240 |
13.9-11.8 |
1 |
1/Var^ |
100% 29,500
90% 25,142
80% 22,569
70% 19,759
60% 17,033
|
14.2
15.6
19.4
25.0
34.0
|
PM-D |
3-Ply |
EVPX55P3PM221A |
55″ |
2.2kW |
190-240 |
13.9-11.8 |
1 |
1/Var^ |
100% 37,300
90% 29,475
80% 26,269
70% 23,483
60% 19,932
|
12.4
17.5
22.2
28.3
38.4
|
PM-D |
3-Ply |
EVPX60P3PM221A |
60″ |
2.2kW |
190-240 |
13.9-11.8 |
1 |
1/Var^ |
100% 40,500
90% 36,700
80% 32,400
70% 28,400
60% 21,650
|
18.9
23.3
29.5
37.7
45.2
|
PM-D |
3-Ply |
^ Variable speed fans require separate variable speed control to adjust fan speed.
Bold red text is data based on testing performed by an accredited lab using ANSI/AMCA 210-07 standard.
OSHA requires these fans to be mounted a minimum of 7’ above the floor
Three Phase wired for 190-240V
PART # |
Size |
HP |
VOLTS |
AMPS |
Phase |
Spd |
@ 0.10” SP CFM |
CFM/Watt |
Drive |
Prop |
EVPX50P3PM223B |
50″ |
2.2kW |
190-240 |
8.4-7.4 |
3 |
1/Var^ |
100% 29,300
90% 24,831
80% 21,775
70% 19,229
60% 16,564
|
14.0
15.2
19.6
26.0
34.8
|
PM-D |
3-Ply |
EVPX55P3PM223B |
55″ |
2.2kW |
190-240 |
8.4-7.4 |
3 |
1/Var^ |
100% 37,500
90% 29,391
80% 26,091
70% 23,047
60% 19,947
|
12.6
17.3
21.9
28.6
38.4
|
PM-D |
3-Ply |
EXPX60P3PM223B |
60″ |
2.2kW |
190-240 |
8.4-7.4 |
3 |
1/Var^ |
100% 40,300
90% 32,667
80% 29,036
70% 25,532
60% 21,970
|
17.8
19.9
25.3
32.9
44.5
|
PM-D |
3-Ply |
^ Variable speed fans require separate variable speed control to adjust fan speed.
Bold red text is data based on testing performed by an accredited lab using ANSI/AMCA 210-07 standard.
OSHA requires these fans to be mounted a minimum of 7’ above the floor
Three Phase wired for 380-460V
PART # |
Size |
HP |
VOLTS |
AMPS |
Phase |
Spd |
@ 0.10” SP CFM |
CFM/Watt |
Drive |
Prop |
EVPX50P3PM223C |
50″ |
2.2kW |
380-460 |
6.2-5.2 |
3 |
1/Var^ |
100% 29,600
90% 24,818
80% 22,101
70% 19,369
60% 16,573
|
14.3
15.3
19.4
25.2
33.5
|
PM-D |
3-Ply |
EVPX55P3PM223C |
55″ |
2.2kW |
380-460 |
6.2-5.2 |
3 |
1/Var^ |
100% 36,800
90% 28,971
80% 25,806
70% 22,723
60% 19,628
|
13.3
18.1
22.9
29.4
39.9
|
PM-D |
3-Ply |
EVPX60P3PM223C |
60″ |
2.2kW |
380-460 |
6.2-5.2 |
3 |
1/Var^ |
100% 40,100
90% 32,455
80% 28,620
70% 25,320
60% 21,637
|
17.4
19.5
24.8
32.0
43.0
|
PM-D |
3-Ply |
^ Variable speed fans require separate variable speed control to adjust fan speed.
Bold red text is data based on testing performed by an accredited lab using ANSI/AMCA 210-07 standard.
OSHA requires these fans to be mounted a minimum of 7’ above the floor