Varifan & Multifan Controls
VARIFAN ELECTRONIC TEMPERATURE/ SPEED CONTROLS
ECS Controls
- Variable stage
- Alarm contacts
- Motor curves
- Hi-lo readings
- Temp ramping
- 120/240 volt
PART # | MODEL # | DESCRIPTION | PROBE (LENGTH) |
E53-8100 | ECS-1M | 1 STAGE DIGITAL – 1 VARIABLE STAGE (10 AMP.) | 2004-1K/30 (30′) |
E53-8200 | ECS-2M | 2 STAGE DIGITAL – 1 VARIABLE STAGE (10 AMP.) 1 ON/OFF STAGE-10 AMP. (HEATING OR COOLING) |
2004-1K/30 (30′) |
E53-8300 | ECS-3M | 3 STAGE DIGITAL – 2 VARIABLE STAGES (6 AMPS EA.) 1 ON/OFF STAGE (10 AMP.) (HEATING OR COOLING) |
2004-1K/30 (30′) |
E53-8400 | ECS-4M | 4 STAGE DIGITAL – 2 VARIABLE STAGES (6 AMPS EA.) 1 ON/OFF STAGE (10 AMP.) (COOLING, SPRINKLER), 1 ON/OFF STAGE (10 AMP.) (HEATING OR COOLING) |
2004-1K/30 (30′) |
E53-8500 | ECS-5M | 5 STAGE DIGITAL – 2 VARIABLE STAGES (6 AMP. EA.) 2 ON/OFF STAGES (10 AMP. EA.) (COOLING) 1 ON/OFF STAGE (10 AMP.) (HEATING OR COOLING) |
2004-1K/30 (30′) |
E53-8650 | DIP-1/R | DIGITAL INLET POSITIONER – FOR 24V ACTUATOR WITH POTENTIOMETER FEEDBACK, 24 VOLT POWER SUPPLY INCLUDED (MUST BE USED IN CONJUNCTION WITH ONE OR TWO ECS-‘M’ CONTROLS) | 2004-1K (10″) |
ECS-C CONTROLS
- Improved enclosure
- Lightening protection
- Up to 4 probes can be connected (2 included with each control)
- 8amp variable stages
- 10amp relays
- Requires 240v supply & 240v variable stage fans
- Core 50 technology
PART # | MODEL # | DESCRIPTION | PROBE (LENGTH) |
E53-8300C | ECS-3C | 2 VARIABLE, 1 OFF/ON RELAY – HEAT & COOL OR MIST (2 PROBES INCLUDED) |
2004-10K (10″) 2004-10K/30 (30′) |
E53-8301C | ECS-3C/120 | 120VOLT – SPECIAL FOR 120VOLT FANS | SAME AS ECS-3C |
E53-8500C | ECS-5C | 2 VARIABLE, 3 OFF/ON RELAYS – 2 HEAT, 3 COOL 1 MIST (2 PROBES INCLUDED) |
2004-10K (10″) 2004-10K/30 (30′) |
E53-8650C | DIP-1C | INLET POSITIONER, 120/240V | 2004-10K (10″) |
E53-3401C | SA-10C | 1 STAGE VARIABLE – NON DIGITAL | 2004-10K (10″) |
E53-4670 | RH-3 | RELATIVE HUMIDITY PROBE **REQUIRES 1 WIRE HARNESS | N/A |
E53-4677 | CRH-3/MGCB | **RED WIRE HARNESS (“C” CONTROLS) | |
E53-4675 | CRH-3/ECS | **BLUE WIRE HARNESS (“M” CONTROLS) | |
E53-4676 | CRH-3/IC | **YELLOW WIRE HARNESS (MSC/IC/LX CONTROLS) | |
E53-9849 | MM-4 | UPLOAD/DOWNLOAD MEMORY STICK |
Provide a minimum of one T15-WD for safety back-up on each control.
2 year warranty unless noted otherwise.
SPECIAL APPLICATION CONTROLS
PART # | MODEL # | DESCRIPTION | PROBE |
E53-4825 | CPS-1H1 | PROPORTIONAL THERMOSTAT FOR MODULATING HOT WATER VALVES. C/W SPECIAL PROBE (10° – 70°C OR 50° – 160°F) SAME FEATURES AS CPS-1 (E53-4800). | 2004-1KHT (6′) |
E53-8700 | TFD-1/R | 1 STAGE VARIABLE 0-10 VOLT FOR 1-10 VOLT DEVICES | 2004-1K (10″) |
E53-8905 | THO-2 | THO-2 C/W TEMPERATURE PROBE (CONTROLS COMBINATION OF TEMPERATURE AND HUMIDITY). | 2004-1K (10″) |
ALSO REQUIRED: | |||
E53-4670 | RH3 | HUMIDITY PROBE | |
E53-4675 | CRH-3/ECS | BLUE CABLE | |
E53-4280 | PEC-1/KIT | PEC-1 C/W SPS-1 HATCHERY VENTILATION CONTROL MAINTAINS STATIC PRESSURE BY CHANGING FAN SPEED IN EITHER EXHAUST OR INTAKE MODE. | N/A |
E53-5130 | IC-410-ND Config# 41E01V5 |
“WATER TROUGH SOW DELIVERY SYSTEM” DELIVERS DESIRED LITRES PER SOW (MAX 150 SOWS PER TROUGH) UP TO 8 TIMES PER DAY. 8 TROUGHS. EXPANDABLE TO 12 (CALL). REQUIRES 1 WATER METER C/W PULSE. |
HEAT MAT/LAMP CONTROLS
E53-4300 | EMC-2 | HEAT MAT/LAMP CONTROL (1 PROBE INCLUDED) 2 ZONE, 2 OUTPUTS OF1000WATTS EACH @ 120V |
2004-1K/30 |
E53-4330 | TLC-4200 | HEAT MAT/LAMP CONTROL (2 PROBES INCLUDED) 2 ZONE, 2 OUTPUTS OF 16 AMPS EACH |
2004-1K |
E53-4305 | GE-INFRA4 | CONTROLS UP TO 4 CRATES’ HEAT LAMPS USING A INFRARED SENSOR. CAN ALSO TURN ON AN ADDITIONAL DRYING HEAT LAMP MANUALLY OR WITH OPTIONAL MOTION DETECTOR AND AUTOMATICALLY SHUT OFF ACCORDING TO A TIMER. INCLUDES 4 INFRARED SENSORS (IRS-1). | |
E53-4306 | PMS-1 | GE-INFRARED MOTION DETECTOR | |
E53-4307 | IRS-1 | INFRARED SENSOR |
POULTRY BIRD SCALES
E53-9500 | OPTI-GAIN 4 | BIRD WEIGH SCALE MASTER CONTROL 45 DAYS (REQUIRES A MIN. OF ONE PLATFORM SCALE OR UP TO A MAX OF FOUR PLATFORM SCALES (OPTI-GAIN 1). | CORE 1000 |
E53-9505 | OPTI-GAIN 5 | BIRD WEIGH SCALE MASTER CONTROL 250DAYS | CORE 2000 |
E53-9510 | OPTI-GAIN KIT | PLATFORM SCALE C/W HANGING HDWR. | |
E53-9520 | X1152 MD-COM | COMMUNICATION CARD (REQ. IF CONNECTING TO PC) | |
E53-9507 | OPTI-GAIN 7 | TURKEY WEIGH SCALE MASTER CONTROL 250 DAYS | CORE 2000 |
E53-9502 | OPTI-GAINKIT/D | TURKEY PLATFORM SCALE PLATFORM |
METERS
E53-1010 | EM10 | TEMPERATURE & HUMIDITY METER |
E53-1020 | EM20 | TEMPERATURE & AIRFLOW METER (ft. per min) |
MANUAL VARIABLE SPEED CONTROLS
PART # | MODEL # | DESCRIPTION | |
E53-4450C | MVS-1C | MANUAL VARIABLE SPEED CONTROL – 12AMP (INTERNAL TRIM POT) | |
E53-4460 | MVS-2 | MANUAL VARIABLE SPEED CONTROL – 6AMP | |
E53-4468 | VSD-1MC | VARIABLE SPEED DRIVE MODULES – CAN BE CONTROLLED BY A 4-20MA SIGNAL OR 0-10 VOLT c/w MANUAL OVER-RIDES. |
10AMP |
E53-4470 | VSD-1MC-20 | 20AMP | |
E53-4472 | VSD-1MC-40 | 40AMP | |
E53-4466 | VSD-1C | 4-20 OR 0-10V INPUT 10AMPS NO OVER-RIDES. | 10 AMP |
OFF/ON ELECTRONIC DIGITAL TEMPERATURE CONTROLS (ALL RELAYS 10 AMPS)
PART # | MODEL # | DESCRIPTION | PROBE |
E53-3600 | MST-1/R | ONE STAGE OFF/ON HEATING AND COOLING (1 PROBE INCLUDED) | 2004-1KLT |
E53-3650 | MST-1H1 | ONE STAGE OFF/ON HOT WATER HEATING C/W SPECIAL 2004-1KHT PROBE TO READ 10-70°C | 2004-1KHT |
E53-3640 | MST-2B | ONE OFF/ON MISTING, EVAPORATIVE COOLING (1 PROBE INCLUDED) C/W 2 STAGE PROGRESSIVE TIMER. OPTIONAL – RH-3 HUMIDITY PROBE C/W BLUE CABLE MAY BE USED TO DELAY MISTING IF HUMIDITY GETS TOO HIGH. | 2004-KLT |
E53-8850C | MST-5C | FIVE OFF/ON RELAYS – RELAYS 1,2,3 COOL STAGES, RELAYS 4 AND 5 HEAT OR COOL. CAN ALSO BE USED TO RUN UP TO 2 SPD FANS USING RELAYS 1,2 AND RELAYS 3,4 AS LOW SPEED/HIGH SPEED (1 PROBE INCLUDED – UP TO 4 PROBES POSSIBLE). | 2004-10K |
EJDDT2 | JDDT2 | DUAL STAGE DIGITAL THERMOSTAT HEAT OR COOL |
CURTAIN/INLET CONTROLS
PART # | MODEL # | DESCRIPTION | PROBE |
E53-4830 | CPS-1/L | AIR INLET/CURTAIN CONTROL 1 ZONE (1 PROBE INCLUDED). OPERATES ON TEMP. TIME BASED, DOWN TO -9.9°C. CAN BE USED AS STATIC PRESSURE CONTROL BY ADDING SPS-1 SENSOR | 2004-1KLT |
E53-4850C | CPS-2C | 2 ZONE CURTAIN CONTROL, OPERATES ON TEMP., TIME BASED WITH DELAYS ON BOTH OPEN/CLOSE (2 PROBES INCLUDED). | 2004-10K |
E53-8800 | CPS-3M/R | 2 ZONE CURTAIN CONTROL – C/W HEAT OFF/ON RELAY, TIME BASED WITH DELAY ON BOTH OPEN/CLOSE (2 PROBES INCLUDED). | 2004-1K |
E53-4270 | SPS-1/R | 1 STATIC PRESSURE SENSOR (REQUIRES CPS-1/L) | N/A |
Note: Also see Genius 210, 215, 220 controls for multiple curtain applications.
VARIFAN COMPONENTS
PART # | MODEL # | COLOUR | DESCRIPTION | Size |
E53-4032 | .250MA | .250MA Fuse (GENIUS) | ||
E53-4026 | .125 MA | FUSE – Power fuse for LX-64X, IC-10, IC-410 | ||
E53-4024 | .75 AMP | FUSE – VDC24 | ||
E53-4030 | 1 AMP | FUSE – Power fuse for DIP-1 | ||
E53-4028 | 1.5 AMP | FUSE – Power fuse for SVIM-/24 | ||
E53-4025 | 3 AMP | FUSE – Actuator Power Fuse for SVIM-1, DIP, CIP | ||
E53-4020 | 5 AMP | FUSE – SVIM-1 120V, SLIM BOARD | ||
E53-4033 | 8 AMP | FUSE – GE-4XX var-2 board | ||
E53-4021 | 10 AMP | FUSE – ECS-1-5M & C Series, MC-22,MST-1H1 MST-2B, EMC-2, CM3-2 |
||
E53-4023 | 15 AMP | FUSE -VPM-1, VPM-2, VSM-2, GE-V2, GE-V1, GE-V4,GE-32,GE-28,MST-1, MVS-1, MVS-2, GE-25, PEC-1 | ||
E53-4027 | 20 AMP | FUSE – TLC-4200, MC-4200SL, CM10-2 | ||
E53-4029 | FB-1 | FUSE BOX | ||
E50-0621 | PLASTIC WATERPROOF CONNECTOR | |||
E53-3460 | 2004-100K | ORANGE | NON DIGITAL TEMP. PROBE (SA-10) | 10″ |
E53-4920 | 2004-1K | RED | DIGITAL TEMP. PROBE (ECS, IC, MST-5, LX) TEMP RANGE: -21 DEG. TO 76 DEG. C, -6 DEG. TO 168 DEG. F |
10″ |
E53-4921 | 2004-1KLT | BLUE | DIGITAL LOW TEMP. PROBE (MST-1, MST-2B) TEMP RANGE: -10 DEG. TO 41 DEG. C, 13.5 DEG. TO 105.5 DEG. F |
10″ |
E53-4922 | 2004-1KHT | RED | DIGITAL HOT WATER PROBE (MST-1H1) TEMP RANGE: 10 DEG. TO 70 DEG. C, 50 DEG. TO 160 DEG. F |
6FT |
E53-4924 | 2004-1K/30′ | RED | 30′ DIGITAL TEMPERATURE PROBE (ECS, IC, MST-5, LX) TEMP RANGE: -21 DEG. TO 76 DEG. C, -6 DEG. TO 168 DEG. F |
30FT |
E53-4930 | 2004/10K | BLACK | PROBE FOR WAVE/GENIUS | 10″ |
E53-4934 | 2004-10K/30 | BLACK | PROBE FOR WAVE/GENIUS | 30FT |
E53-4925 | 2004-5K/SV1 | RED | SV1 SVIM PROBE | 10″ |
E53-4927 | 2004-5K/SV30 | SV1/30 SVIM PROBE | 30FT | |
E53-4915 | 2 CONDUCTOR, 18 GAUGE SHIELDED WIRE (PER FOOT) (FOR EXTENDING TEMPERATURE PROBES) |
|||
E53-4929 | 2004-1K/F | FAST READING PROBE (4 TIMES FASTER) | 10″ | |
E53-4928 | 2004-1KX2 | RED | DOUBLE LECTURE PROBE | 10″ |
Note: 2 year warranty unless noted otherwise.
MULTIFAN AND MISCELLANEOUS CONTROLS (1 YEAR WARRANTY)
PART # | MODEL # | DESCRIPTION |
E53-5402 | T15-WD | SINGLE SPEED THERMOSTAT 10 AMP. 110/220 VOLT |
EJDDT2 | JDDT2 | TWO STAGE DIGITAL THERMOSTAT 10AMP 90-255 VOLT 50/30HZ |
E53-5403DV | T10-3 | THREE PHASE THERMOSTAT |
E53-1025 | 25 | DWYER #25 MARKII MANOMETER 0″-3″ S.P. |
E53-1026 | A-101 | RED GAUGE OIL – 3/4 oz BOTTLE |
E53-1030 | 2000-00D | MAGNEHELIC PRESSURE GAUGE (0″-.25″ WC / 0-125 PA) |
E53-7676 | 05-09-060 | 1/4″ CLEAR TUBE (10 FEET) |
E53-5410 | PECO | NEMA 4X 1SPEED THERMOSTAT |
VARIFAN CONTROLS
Recommended for replacement only of existing controls.
PART # | MODEL # | DESCRIPTION | PROBE |
E53-4500 | MST-3/R | THREE STAGE OFF/ON | |
E53-4990 | RCM-40 | PC LINK (ESC-M) | |
E53-9320 | MC-22/R | TWO VARIABLE 6AMP STAGES, 2 OFF/ON 10AMP HEAT/COOL STAGES | 3@12″ |
E53-9000 | LX-641-C | ONE INTERNAL RELAY (HEAT, COOL OR SPRINKLER) EXPANDABLE BY UP TO 4 VARIABLE STAGES (BY ADDING VPM-1, VPM-2 OR VSM-2 MODULES) AND 1 INLET (BY ADDING SVIM-1/24 OR SVIM-1 MODULE) |
3@30′ |
E53-9005 | LX 641-F | ||
E53-9010 | LX 642-C | TWO INTERNAL RELAYS (HEAT, COOL, SPRINKLER) EXPANDABLE UP TO 4 VARIABLE STAGES |
3@30′ |
E53-9015 | LX 642-F | ||
E53-9020 | LX 644-C | FOUR INTERNAL RELAYS (HEAT, COOL, 1 SPRINKLER) EXPANDABLE UP TO 4 VARIABLE STAGES |
3@30′ |
E53-9025 | LX 644-F | ||
E53-9030 | LX-644/2-C | ||
E53-9035 | LX-644/2-F | ||
E53-9110 | LX-646/2-C | SIX INTERNAL RELAYS (HEAT, COOL, 1 SPRINKLER) EXPANDABLE UP TO 4 VARIABLE STAGES |
5@10″ |
E53-9115 | LX-646/2-F | ||
E53-9100 | LX-646/4-C | ||
E53-9105 | LX-646/4-F | ||
E53-9040 | VPM-1 | ONE VARIABLE STAGE MODULE 6 AMP. | N/A |
E53-9045 | VPM-2 | TWO VARIABLE STAGE MODULE 6 AMP. EACH. | N/A |
E53-5260 | SVIM-1 | DIGITAL INLET MODULE – 110V, FOR USE WITH 110VOLT ACTUATOR | 1@30′ |
E53-5270 | SVIM-1/24 | DIGITAL INLET MODULE -24V (SUPPLIES 24V OUTPUT TO ACTUATOR) | 1@30′ |
E53-4960 | VSM-2 | TWO VARIABLE FAN STAGES, 6 AMP C/W TOGGLE OVER-RIDE | |
E53-5110 | IC-610 | INTELLIGENT CONTROL (SPECIFY CONFIGURATION #) | N/A |
E53-4940 | CM10-2 | TWO ON/OFF STAGES, 10 AMP. EACH. MAX. 1 1/2 H.P. | N/A |
E53-4955 | CIP-1 | CURTAIN/ INLET POSITIONER, 3 AMP. MODULE | N/A |
E53-4963 | VSM-2/2 | ONE VARIABLE FAN STAGE AT 12 AMP. C/W MAN. OVERRIDE | N/A |
E53-4967 | SPS-24 | 24VOLT VAC TRANSFORMER ONLY | N/A |
E53-4965 | VDC-24 | 24 VOLT TRANSFORMER WITH ENCLOSURE (DC VOLTAGE) | N/A |
E53-4970 | CM3-2 | TWO ON/OF STAGES, 4 AMP. EACH | N/A |
E53-4875 | R.B.-2 | RELAY BOX (25 AMP., 2 H.P.) | N/A |
E53-5111 | CM-8 | CM-8 CONFIGURATION CHIP FOR IC/LX CONTROLS |
Farmquest Communication Systems
FARMQUEST COMMUNICATION SYSTEM (DIRECT WIRED OR WIRELESS)
View and manage your controls using internet (free access) to online server.
PART # | MODEL# | DESCRIPTION |
E53-9154C | WEBGATE C | COMPACT WIRELESS WEBGATE FOR WIRELESS CONNECTION TO FARMQUEST THRU INTERNET SERVICE |
E53-9154 | WEBGATE 3G/HW | WEBGATE 3G/HW INCLUDES ETHERNET PORT AND NETIN-2 CARD FOR HARD WIRE CONNECTION TO CONTROLS. CONTROLS REQUIRE COMMUNICATION CARDS |
E53-9161 | WEBGATE 3G-C/RF | WEBGATE WITH CELLULAR CONNECTION INCLUDED: RF-IN CARD FOR WIRELESS CONNECTION TO CONTROLS |
E53-9162 | DOORLOCK/IDC | ELECTRICAL DOOR ACCESS 5 RFiD |
E53-9054 | RF-P4 | MULTI PURPOSE 4 INPUT MODULE (WIRELESS) |
WI FARM 3G ANTENNAS & ANTENNA CONTROL CARDS FOR WIRELESS SYSTEM
PART # | MODEL# | DESCRIPTION |
E53-9155 | RF-IN1 | ANTENNA CARDS FOR CORE 100 CONTROLS (ECS-C, GE-25, 28, L2) |
E53-9156 | RF-IN2 | ANTENNA CARDS FOR CORE 1000/2000 CONTROLS (GENIUS, OPTIGAIN) |
E53-9157 | RF-XTEND | ANTENNA FOR EXTERIOR MOUNT – USED TO EXTEND RANGE OF RF ACCESS ANTENNAS OR AROUND OBSTRUCTIONS. |
E53-9158 | RF-ACCESS | WIRELESS SYSTEM ANTENNA – USED TO SEND SIGNAL THRU WALLS AND BETWEEN BUILDINGS UP TO 1600FT BETWEEN EACH ANTENNA (DISTANCE BASED ON DIRECT VIEW LINE OF SIGHT.) |
COMMUNICATION CARDS FOR DIRECT WIRE SYSTEM
PART # | MODEL# | DESCRIPTION |
E53-9797 | X1264/COM | COM CARD FOR GENIUS GE25, GE28, GE-6X |
E53-9830 | X1202/COM | COM CARD FOR: CORE 1000, 2000, GENIUS 4X, 4XLS AND AGRI-MANAGER CONTROLS |
E53-9160 | NETIN-2 | COM CARD FOR: CORE 50, 100, GE-L2, ECS-C |
E53-9520 | X1152 MDCOM | COM CARD FOR OPTIGAINS |
FARM SITE COMMUNICATION SYSTEM- USING SOFTWARE ON PERSONAL PC
3G “WI Farm” wireless communication system.
PART # | MODEL# | DESCRIPTION |
E53-9152 | RAN-1 | RADIO ACCESS NETWORK ANTENNA USB KEY FOR PC |
Farm-site software for your PC is free.
**Note: Controls must have RF-IN or RF-IN2 wireless cards to complete system.