Genius GE-6x Series Control System
Genius Ge-6x Series Control System Features
- Core 1000 technology
- Quick disconnect terminals
- Large 2-1/2″ X 1-3/4″ screen
The Genius 6x Series can operate 1 to 4 variable stages by adding a GE-V1 module (1 stage variable) or 1 or 2 GE-V2 modules (2 stage variable). There are up to six 10amp relays, depending on the model chosen, that can be used for cooling, heating, heating pad, clock output, sprinkler or misting. One alarm relay and up to two 0-10 chimney dampers can be controlled by adding GE-MO10, 0-10v modules. The Genius Series can be ordered with an internal 120volt inlet board (IN1/120KIT) or a two inlet board (IN2/120KIT). All Genius models can operate up to two additional inlets by adding a GE-AIR/1 or a GE-AIR/2 inlet module (also compatible with VPM-2, VSM-2 and SVIM-1 inlet modules). Up to five 10k sensors may be used with one being designated for outside use.
New logic in 2017 includes:
- Activation of stage 1 or 2 if heat is on
- Option to operate variable heaters or heat pads using GE-m010 0-10v module
The Genius 641,642,644,646 are now able to connect to SVIM-1 inlet modules as well as VPM-2 to allow easy LX master control replacements with genius master controls. Note: SVIM bottom board may have to be updated depending on age.
Note: GE-641/642/644 price includes 1-30ft and 2-10″sensors. The GE-646 includes 1-30ft and 4-10″ sensors. Order additional sensors if required. The program allows for Celsius or Fahrenheit readings.
Control System Specifications
PART # | MODEL # | DESCRIPTION |
E53-9700 | GE-641 | MASTER CONTROL (ONE RELAY) |
E53-9705 | GE-641/IN1/120 KIT | ONE RELAY, ONE INLET 120VOLT |
E53-9710 | GE-641/IN2/120 KIT | ONE RELAY, TWO INLETS 120VOLT |
E53-9720 | GE-642 | MASTER CONTROL (TWO RELAYS) |
E53-9725 | GE-642/IN1/120 KIT | TWO RELAYS, ONE INLET 120VOLT |
E53-9730 | GE-642/IN2/120 KIT | TWO RELAYS, TWO INLETS 120VOLT |
E53-9740 | GE-644 | MASTER CONTROL (FOUR RELAYS) |
E53-9745 | GE-644/IN1/120 KIT | FOUR RELAYS, ONE INLET |
E53-9750 | GE-644/IN2/120 KIT | FOUR RELAYS, TWO INLETS |
E53-9760 | GE-646 | MASTER CONTROL (SIX RELAYS) |
E53-9765 | GE-646/IN1/120 KIT | SIX RELAYS, ONE INLET 120V |
E53-9770 | GE-646/IN2/120 KIT | SIX RELAYS, TWO INLETS 120V |
*Note: Add GE-V1 or GE-V2 variable speed modules to control prices above and/or GE-AIR inlet modules as application requires.
E53-9775 | GE-V1 | ONE VARIABLE STAGE MODULE 10AMP |
E53-9780 | GE-V2 | TWO VARIABLE STAGE MODULES 10AMP EACH |
E53-9785 | GE-AIR/1-120V | ONE INLET 120V MODULE (NO DISPLAY) |
E53-9790 | GE-AIR/2-120V | TWO INLETS 120V MODULE (NO DISPLAY) |
E53-9792 | GE-MO10-120V | 0-10 VOLT MODULE (REQ’D FOR EACH CHIMNEY DAMPER) |
E53-9715 | GE-R4 | FOUR TOGGLE OFF/ON, 2HP RELAY BOX |
E53-5402 | T15-WD | ONE SPEED THERMOSTAT 10AMP. (SAFETY OVER-RIDE) |
Note: Provide at least one safety T15-WD over-ride for GE-641, GE-642, and two safety over-rides for GE-644/646.
Genius Control System
PART # | MODEL # | DESCRIPTION |
E53-9705/24 | GE-641/IN1/24 KIT | ONE RELAY, ONE INLET 24VOLT |
E53-9725/24 | GE-642/IN1/24 KIT | TWO RELAYS, ONE INLET 24VOLT |
E53-9785/24 | GE-AIR/1/24V | 24VOLT AIR INLET MODULE (GE641-646) |
E53-4930 | 2004-10K | 10″ TEMPERATURE PROBE (ADD AS REQUIRED) |
E53-4934 | 2004-10K/30 | 30FT TEMPERATURE PROBE (ADD AS REQUIRED) |
E53-4670 | RH-3 | HUMIDITY PROBE |
E53-4677 | CRH-3/MGCB | RED WIRE HARNESS REQUIRED WITH RH-3 |
Genius “Core 100” Technology Controls
Features:
Quick key pads for grouping settings, 3/4″x2″ LCD screen, 30 day history, up to 4 inside probes, one outside probe, humidity probe option; use RH3 and red harness and potentiometer feed back (order extra probes as required).
PART # | MODEL # | DESCRIPTION |
E53-9835 | GE-25 | 2 Internal variable stages, 5 multi-purpose off/on relays for up to 5 additional cooling stages, up to 2 heating stages, 1 two level mist stage or 1 inlet using 2 relays with pot feed back, 1-10k probe included. |
E53-9840 | GE-28 NOTE: DISCONTINUED parts only avail. |
2 Internal variable stages, 8 multi-purpose relays for up to 8 additional cooling stages, up to 4 heater stages 1 two level mist, 1 water meter input. |
E53-9846 | AIRIN-1 | Inlet board option for GE-28 only (1 inlet) |
E53-9848 | AIRIN-2 | Inlet board option for GE-28 only (2 inlet) |
E53-9849 | MM-4 | Memory stick for core 100 (to transfer settings from control to control) |
Belimo Actuator Control For Chimney Dampers & Inlet Shutter
0-10v models can be operated using GE-6x or GE-425/430 controls.
Spring return can be operated by relays of all controls.
PART # | MODEL # | DESCRIPTION |
**E57-8015 | NMX120-SR | BELIMO 120V 0-10V SIGNAL |
E57-8011 | BELIMO MOISTURE RESISTANT ENCLOSURE & MOUNTING BRKT (MOUNTS ON SIDE OF CHIMNEY MODULE) |
** While Quantities Last
Genius GE-4x Series Control System
Easy to view (2-1/2″ x 1-3/4″) LCD screen
6 HOT key pads
4 variable stages, 6 amp c/w ability to boost 10 more amps by using GE-V1 or GE-V2 modules. NOTE: Two of the variable stages can be used as manual variable stages to run circulation fans. 10, 15 or 20 2HP relay contactors for up to 12 cool stages, 6 heat, 2 clocks c/w 6 off/on cycles, 1 mist and 6 inlets (NOTE: each inlet requires 2 relays).
Program features SolarWall Boost Logic, outdoor compensation, temperature and min speed curves, dehumidification logic, night set point, water counter (1), natural ventilation and tunnel logic to operate curtains and tunnel inlets by time mode or potentiometer feed back.
* Core 1000 technology
PART # | MODEL # | DESCRIPTION |
E53-9850 | GE-410R | 4 VARIABLE STAGES, 10 OFF/ON RELAYS, 1 PROBE |
E53-9860 | GE-415R | 4 VARIABLE STAGES, 15 OFF/ON RELAYS, 1 PROBE |
E53-9870 | GE-420R | 4 VARIABLE STAGES, 20 OFF/ON RELAYS, 1 PROBE |
Required Additional Items
PART # | MODEL # | DESCRIPTION |
E53-9211 | CM-128 | CONFIGURATION CHIP (FOR UP LOADING & DOWN LOADING SETTINGS) |
E53-4930 | 2004/10K | PROBE (ADD UP TO 6 PER CONTROL) |
E53-5402 | T-15-WD | SAFETY OVER-RIDE (3-4 RECOMMENDED) |
Options
PART # | MODEL # | DESCRIPTION |
E53-4670 | RH-3 | HUMIDITY PROBE |
E53-4677 | CRH-3/MGCB | RED WIRE HARNESS – REQUIRED WITH RH-3 |
E53-9055 | 750JLPRS | WATER METER C/W PULSE (3/4″ CONNECTION) REPLACEMENT ONLY |
E53-9058 | 750VPD-L | WATER METER C/W PULSE (3/4″ CONNECTION) |
E53-9830 | X1202 | PC COMMUNICATION BOARD GE-4X / AGRI-MANAGER |
E53-9775 | GE-V1 | GE-V1 MODULE, 1 STAGE VARIABLE 10 AMP BOOSTER |
E53-9780 | GE-V2 | GE-V2 MODULE, 2 STAGE 8 AMP BOOSTER PER STAGE |
Genius Light Control
* Core 100 technology
Up to two dimming zones, 20 growth periods, 5 cycles per day, 3 stimulation cycles. Two out-puts of 1800 watts @ 120volt.**
GE-l2/LED specific for LED dimmable lights
PART # | MODEL # | DESCRIPTION |
E53-5154 | GE-L2/LED | TWO OUTPUTS FOR 8 AMPS C/W OVER-RIDES SPECIFIC FOR LED LIGHTING |
E53-5145 | GE-L2 | DIMMABLE LIGHT CONTROL C/W MANUAL OVER-RIDES |
Voltage capacity can be boosted by using GE-V1 and GE-V2 modules or GE-V2/LED for GE-L2/LED control.
Genius GE-2x Series Control System
For Dual Ventilation/Natural Curtain Ventilation Systems
2-1/2″ x 1-3/4″ LCD screen – 6 HOT keys
2 Variable stages, 10,15 or 20 2hp off/on relays to operate up to 6 natural ventilation curtains or 4 natural curtains and 2 ceiling inlets in a dual ventilation system.
Note: Each curtain or inlet requires 2 relays. Up to 8 additional cool stages, 4 heat stages, 1 mist/soaking stage, 2 clock, 1 feeding clock with 6 off/on cycles. Toggle over-rides on all stages. 4 inside probes, 1 outside probe. Compensation requires static pressure GE-SP1/KIT.
Special logic for dual ventilation and curtain systems includes progressive timer curtain control and outdoor compensation to manage curtain control set points. Feed consumption history and alarm (current detection device and/or proximity sensor required) humidity over-ride logic. Water consumption history (meter required).
* Core 1000 technology
PART # | MODEL # | DESCRIPTION |
E53-9910 | GE-210R | 2 VARIABLE STAGES, 10 OFF/ON RELAYS, 1 PROBE |
E53-9915 | GE-215R | 2 VARIABLE STAGES, 15 OFF/ON RELAYS, 1 PROBE |
E53-9920 | GE-220R | 2 VARIABLE STAGES, 20 OFF/ON RELAYS, 1 PROBE |
Required Additional Items
PART # | MODEL # | DESCRIPTION |
E53-9211 | CM-128 | CONFIGURATION CHIP (ADD ONE PER CONTROL) |
E53-4930 | 2004/10K | PROBE (ADD UP TO 4 PER CONTROL) |
E53-5402 | T-15-WD | SAFETY OVER-RIDE (1-2 RECOMMENDED) |
Options
PART # | MODEL # | DESCRIPTION |
E53-4670 | RH-3 | HUMIDITY PROBE |
E53-4677 | RED WIRE HARNESS – REQUIRED WITH RH-3 | |
E53-9055 | 750JLPRS | WATER METER W/PULSE COUNT (3/4″ CONNECTION) REPLACEMENT ONLY |
E53-9058 | 750VPD-L | WATER METER C/W PULSE (3/4″ CONNECTION) |
E53-9057 | 1000JLPS | WATER METER W/PULSE COUNT (1″ CONNECTION) |
E53-9830 | X1202 | PC COMMUNICATION BOARD GE-4X / AGRI-MANAGER |
E53-9898A | CSD-1A | CURRENT DETECTOR (REQUIRED FOR FEED LOGIC) |
E53-9895 | GE-SP1/KIT | STATIC PRESSURE PROBE |
Call for other options such as adding 2 variable stages, GE boosters and logic features.
Genius Feed Bin Monitoring System
An easy and effective way to manage feed bin inventory levels & feed consumption rates. This system consists of a master control GE-BIN4, which monitors up to 4 feed bins. The SB15K shear beam requires bin to be lifted by approximately 8-10″.
* Core 2000 technology
PART # | MODEL # | DESCRIPTION |
E53-9605 | GE-BIN4 | MASTER CONTROL (MONITOR UP TO 4 FEED BINS) |
E53-9610SB | GE-FBT-1SB | FEED TRANSMITTER (1 PER BIN) FOR SB15K |
E53-9611 | GE-LIM (1 PER BIN) | LIGHTNING ISOLATOR MODULE WITH TRANSFORMER |
E53-9615 | SB15K/KIT | SHEAR BEAM KIT W/SUPPORT -1 PER LEG (6 MAX/BIN) MAX LOAD 7.5 METRIC TON |
E53-9618 | DSB-22K/KIT | 10MT LOAD CELL C/W SUPPORT – 1 PER LEG |
E53-9898A | CSD-1A | 1-4 CURRENT DETECTOR (1 PER AUGER) |
NOTE: Bins must have a max of 6 legs.
Genius GE-4xxLSR Series Control System
Genius GE-415LSR and GE-420LSR Controls
Large LCD screen (4-1/2″ x 2-1/2″)
6 HOT key pads
4 variable stages, 6amp c/w ability to boost 10 more amps by using GE-V1 or GE-V2 modules. Up to 11 inside probes and 1 outside. 15 or 20 2HP relay contactors for up to 20 cool stages, 12 heat, 8 clocks with 6 off/on cycles, 1 mist expandable to 6 for a total of 8 adding x1200 input board, 1 water input and 8 inlets (NOTE: each inlet requires 2 relays). Up to 6 feed relays with 12 off/on cycles with optional current detection for alarm and feed history. Up to 8 waterflush relay options.
Optional 0-10V board allows control of up to 2 chimney dampers using Belimo or any other 0-10V actuator, frequency drives or light slaves. Option light module GE-V4/S-4 for control of dusk to dawn light programs (designed for fluorescents and incandescents) Off/On toggle switches on all stages. Program features SolarWall Boost Logic, outdoor compensation, dehumidification logic, temperature and min speed curves, misting restriction times, night set point, water counter, natural ventilation, dual ventilation, tunnel logic to operate curtains and tunnel inlets. Static pressure compensation requires GE-SP1/KIT.
Two light programs, Core 2000 Technology.
PART # | MODEL # | DESCRIPTION |
E53-9865 | GE-415 LSR | 4 VARIABLE, 15 OFF/ON, 1 PROBE INCLUDED |
E53-9875 | GE-420 LSR | 4 VARIABLE, 20 OFF/ON, 1 PROBE INCLUDED |
Required Additional Items
PART # | MODEL # | DESCRIPTION |
E53-4930 | 2004/10K | PROBE (ADD UP TO 11 PER CONTROL) |
E53-5402 | T-15-WD | SAFETY OVER-RIDE (3-4 RECOMMENDED) |
E53-9522 | CM-512M | CONFIGURATION CHIP (FOR UP LOADING & DOWN LOADING SETTINGS) |
Options
PART # | MODEL # | DESCRIPTION |
E53-4670 | RH-3 | HUMIDITY PROBE |
E53-4677 | RED WIRE HARNESS REQUIRED WITH RH-3 | |
E53-9055 | 750JLPRS | WATER METER W/PULSE COUNT (3/4″ CONNECTION) REPLACEMENT ONLY |
E53-9058 | 750VPD-L | WATER METER C/W PULSE (3/4″ CONNECTION) |
E53-9057 | 1000JLPS | WATER METER W/PULSE COUNT (1″ CONNECTION) |
E53-9287 | GE-V4/S4 | LIGHT MODULE – 4 OUTPUTS 1800 WATTS EA. W/ MAN OVER-RIDE (NOT LIKELY TO WORK SATISFACTORY WITH NEW LED LIGHTING) |
E53-9878 | X1201/640ER | 0-10V 2 OUTPUTS BOARD (FOR BELIMO ACTUATORS, LIGHTS) |
E53-9830 | X1202/640ER | PC COMMUNICATION BOARD |
E53-9775 | GE-V1 | GE-V1 MODULE – 1 STAGE 10AMP BOOSTER |
E53-9780 | GE-V2 | GE-V2 MODULE – 2 STAGE 10AMP BOOSTER |
E53-9895 | GE-SP1/KIT | STATIC PRESSURE PROBE |
E53-9898A | CSD-1A | CURRENT DETECTION (FOR FEED LOGIC) REQ 1 PER FEED RELAY |
E53-9827 | X1200/INPUT | 9 INPUT BOARD (ADDS 7 WATER INPUTS) |
Genius GE-425LSR and GE-430LSR Controls
Large LCD screen (4-1/2″ x 2-1/2″)
12 HOT key pads
- 4 variable stages, 6amp c/w ability to boost 10 more amps by using GE-V1 or GE-V2 modules. 1 outside probe, 11 inside temp. probes 25 or 30 2HP relay contactors for up to 24 cool stages, 12 heat, 8 clocks, 4 mist and 8 inlets (NOTE: each inlet requires 2 relays).
- Up to 6 feed relays with 12 off/on cycles with optional current detection for alarm and feed history (effective June 2012).
- One water counter input. Expandable to 6 for total of 8 adding x1200 input board.
- Optional 15 or 20 relay slave modules to maximize cool stages, heater stages and inlets to a maximum of 16.
- Optional 0-10V board allows control of up to 2 chimney dampers using Belimo or any other 0-10V actuator, frequency drives, light slaves.
- Optional light module GE-V4/S-4 for control of dusk to dawn light programs (designed for fluorescents and incandescents).
- Off/On toggle switches on all stages. Program features SolarWall Boost Logic, outdoor compensation, dehumidification logic, temperature and min. speed curves, misting restriction times, night set point, natural ventilation and tunnel logic to operate curtains and tunnel inlets. Static pressure compensation requires GE-SP1/KIT.
- Two light programs.
PART # | MODEL # | DESCRIPTION |
E53-9880 | GE-430LSR | 4 VARIABLE, 30 OFF/ON, 1 PROBE INCLUDED |
E53-9885 | GE-425LSR | 4 VARIABLE, 25 OFF/ON, 1 PROBE INCLUDED |
E53-9930 | GE-ST30LSER | 30 OFF/ON RELAYS, 1 PROBE INCLUDED |
E53-9925 | GE-ST25LSER | 25 OFF/ON RELAYS, 1 PROBE INCLUDED |
Required Additional Items
PART # | MODEL # | DESCRIPTION |
E53-4930 | 2004/10K | PROBE (ADD UP TO 11 PER CONTROL) |
E53-5402 | T-15-WD | SAFETY OVER-RIDE (4-6 RECOMMENDED) |
E53-9522 | CM-512M | CONFIGURATION CHIP (FOR UP LOADING & DOWN LOADING SETTINGS) |
Options
PART # | MODEL # | DESCRIPTION |
E53-9881 | GE-SL15 | 15 RELAY MODULE, 8 POT BOARD INCLUDED |
E53-9882 | GE-SL20 | 20 RELAY MODULE, 8 POT BOARD INCLUDED |
E53-4670 | RH-3 | HUMIDITY PROBE |
E53-4677 | RED WIRE HARNESS REQUIRED WITH RH-3 | |
E53-9055 | 750JLPRS | WATER METER /W PULSE (3/4″ CONNECTION) – REPLACEMENT ONLY |
E53-9058 | 750VPD-L | WATER METER C/W PULSE (3/4″ CONNECTION) |
E53-9057 | 1000JLPS | WATER METER W/PULSE COUNT (1″ CONNECTION) |
E53-9287 | GE-V4/S4 | LIGHT MODULE – 4 OUTPUTS 1800 WATTS EA. W/ MAN OVER-RIDE (NOT LIKELY TO WORK SATISFACTORY WITH NEW LED LIGHTING) |
E53-9270 | GE-V2/LED | LED LIGHT MODULE, 2 OUTPUTS OF 8 AMPS EACH C/W MANUAL OVER-RIDES. OPERATES MOST DIMMABLE LED LIGHTS |
E53-9878 | X1201/640ER | 0-10V 2 OUTPUTS BOARD (FOR BELIMO) |
E53-9775 | GE-V1 | GE-V1 MODULE – 1 STAGE 10AMP BOOSTER |
E53-9780 | GE-V2 | GE-V2 MODULE – 2 STAGE 10AMP BOOSTER |
E53-9898A | CSD-1A | CSD-1 CURRENT DETECTION (FOR FEED LOGIC) 1 PER RELAY REQ’D |
E53-9895 | GE-SP1/KIT | STATIC PRESSURE PROBE C/W ADAPTOR |
E53-9827 | X1200/INPUT | 9 INPUT BOARD (ADDS 7 WATER INPUTS) |
Genius GE-Nutri - Multi Program Feed Control System
- Can now manage 5 program types: multi-feed, feed auger, chain auger, feed auger drop and chain feeder drop
- Can operate up to 4 actuators c/w potentiometer
- Up to 4 bins 6 cycle times per day
- Feed usage history possible using current sensors on each bin
- Can be connected to FarmQuest management system for remote control using the internet
PART # | MODEL # | DESCRIPTION |
E53-4335 | GE-NUTRI | GE-NUTRI FEED CONTROL |
E53-9898A | CSD-1A | ADJUSTABLE CURRENT SENSORS (UP TO 4) |
E53-9715 | GE-R4 | 4 TOGGLE OFF/ON 2HP RELAY BOX (RECOMMENDED) |
E53-3043 | X1314/R4 | RELAY BOARD WITH 4 RELAYS |
*Core 2000 technology
Use RF-IN2 and web-gate for FarmQuest system.
Genius Parts
GENIUS 6X CONTROL SYSTEM PARTS
PART # | DESCRIPTION |
E53-9701 | X1222/GE GE-64X TOP BOARD ONLY GE(1,2,4,6) |
E53-9702 | X1238/GE641 GE-641 BOTTOM BOARD ONLY |
E53-9722 | X1238/GE642 GE-642 BOTTOM BOARD ONLY |
E53-9742 | X1237/GE644 GE-644 BOTTOM BOARD ONLY |
E53-9762 | X1237/GE646 GE-646 BOTTOM BOARD ONLY |
E53-9824 | X1210 M-CORE 1000 PROCESSOR BOARD GE 6X/4X |
E53-9707 | X1239/IN1 IN1/120 120V ONE INLET BOARD -GE-641-646 |
E53-9712 | X1239/IN2 IN2/120 120V TWO INLET BOARD-GE-641-646 |
E53-9708/24 | X1240/IN/24 IN1/24 24VOLT & TRANSFORMER-GE-641-646 |
E53-9707/24 | X1218/IN1/24 24 VOLT INLET BOARD GE-641-646 |
E53-9787/24 | X1220/IN1/24 24 VOLT INLET BOARD GE AIR MODULE |
E53-9795 | P-8388 24 VOLT TRANSFORMER |
E53-9776 | X1243/GEV1 GE-V1 BOTTOM BOARD ONLY – GE-V1 MODULE |
E53-9781 | X1243/GEV2 GE-V2 BOTTOM BOARD ONLY – GE-V2 MODULE |
GENIUS 4X, 420-LS, 430-LS, AGRI MANAGER PARTS
PART # | DESCRIPTION |
E53-9820KIT | X1184/1640ERKIT – 5 RELAY BOARD |
E53-9828KIT | X1192/1640ERKIT – 5 TOGGLE BOARD |
E53-3044 | X1206/4 TOGGLE BOARD GE-4X/GE-430/AGRM |
E53-9829/2 | X1206/2 TOGGLE BOARD 2VAR GE-2X |
E53-9821 | X1204 2 VARIABLE BOARD GE-4X/GE430/AGRM |
E53-9822 | X1205/8 POT BOARD GE-4X/GE-430/AGRM |
E53-9823 | X1224 MASTER MAIN BOARD GE-4X |
E53-9824 | X1210 M-CORE 1000 PROCESSOR BOARD GE-4X/6X |
E53-9825 | X1222/GE2211 DISPLAY BOARD GE-4X |
E53-9826 | X1416 OUTPUT SLIM BOARD GE-4X/GENIUS-430/IT |
E53-9827 | X1200 9 INPUT BOARD (PROBE/HUM) GE-4X/AGRM |
E53-9834 | X1199 SENSOR & COMM. BOARD GE-430/AGRM |
E53-9832 | LPS63B 12 VOLT 60W POWER SUPPLY GE4X,43O/AGRM |
E53-9876 | X1224 MAIN BOARD 420-LS |
E53-9877 | X1285 DISPLAY/INTERFACE 420-LS |
E53-9891 | X1323 MAIN BOARD ONLY GE-430 |
E53-9892 | X1211 CORE 2000 MICROPROCESSOR BOARD GE-430/AGRM |
E53-9890 | X1323/LSR KIT (MAIN BOARD C/W MICROPROCESSOR) GE-430 |
E53-9893 | X1226 MASTER MAIN BOARD ONLY / AGRM |
E53-9894 | X1228 DISPLAY BOARD / AGRM |
E53-9833 | PLASTIC CAPS FOR FRONT COVER |
E53-4034 | 216-315 FUSE 3.15 AMP FOR 12VOLT POWER SUPPLY LPS63B |
E53-9883 | 1333/SLRL MINI SLIM BOARD -RELAY MODULE |
E53-9884 | X1322 DISPLAY BOARD FOR GENIUS 430 |
GENIUS GE-25,GE-28 PARTS
PART # | DESCRIPTION |
E53-9837 | X1281/GE-25 TOP BOARD ONLY |
E53-9838 | 3281/GE-25 TOP BOARD AND HOUSING |
E53-9839 | X1282/GE-25 BOTTOM BOARD ONLY |
E53-9842 | X1277/GE-28 TOP BOARD ONLY |
E53-9844 | X1278/GE-28 BOTTOM BOARD ONLY |
E53-9845 | X1279/VIN-2 GE-25/GE-28 VARIABLE BOARD ONLY |
E53-9847 | X1255/C100 GE-25/GE-28 CORE 100 MICROPROCESSOR BOARD |