Details for Genius Control System and Parts

Genius GE-6x Series Control System

Genius Ge-6x Series Control System Features

  • Core 1000 technology
  • Quick disconnect terminals
  • Large 2-1/2″ X 1-3/4″ screen

The Genius 6x Series can operate 1 to 4 variable stages by adding a GE-V1 module (1 stage variable) or 1 or 2 GE-V2 modules (2 stage variable). There are up to six 10amp relays, depending on the model chosen, that can be used for cooling, heating, heating pad, clock output, sprinkler or misting. One alarm relay and up to two 0-10 chimney dampers can be controlled by adding GE-MO10, 0-10v modules. The Genius Series can be ordered with an internal 120volt inlet board (IN1/120KIT) or a two inlet board (IN2/120KIT). All Genius models can operate up to two additional inlets by adding a GE-AIR/1 or a GE-AIR/2 inlet module (also compatible with VPM-2, VSM-2 and SVIM-1 inlet modules). Up to five 10k sensors may be used with one being designated for outside use.

New logic in 2017 includes:

  • Activation of stage 1 or 2 if heat is on
  • Option to operate variable heaters or heat pads using GE-m010 0-10v module

The Genius 641,642,644,646 are now able to connect to SVIM-1 inlet modules as well as VPM-2 to allow easy LX master control replacements with genius master controls. Note: SVIM bottom board may have to be updated depending on age.

Note: GE-641/642/644 price includes 1-30ft and 2-10″sensors. The GE-646 includes 1-30ft and 4-10″ sensors. Order additional sensors if required. The program allows for Celsius or Fahrenheit readings.

Control System Specifications

PART # MODEL # DESCRIPTION
E53-9700 GE-641 MASTER CONTROL (ONE RELAY)
E53-9705 GE-641/IN1/120 KIT ONE RELAY, ONE INLET 120VOLT
E53-9710 GE-641/IN2/120 KIT ONE RELAY, TWO INLETS 120VOLT
E53-9720 GE-642 MASTER CONTROL (TWO RELAYS)
E53-9725 GE-642/IN1/120 KIT TWO RELAYS, ONE INLET 120VOLT
E53-9730 GE-642/IN2/120 KIT TWO RELAYS, TWO INLETS 120VOLT
E53-9740 GE-644 MASTER CONTROL (FOUR RELAYS)
E53-9745 GE-644/IN1/120 KIT FOUR RELAYS, ONE INLET
E53-9750 GE-644/IN2/120 KIT FOUR RELAYS, TWO INLETS
E53-9760 GE-646 MASTER CONTROL (SIX RELAYS)
E53-9765 GE-646/IN1/120 KIT SIX RELAYS, ONE INLET 120V
E53-9770 GE-646/IN2/120 KIT SIX RELAYS, TWO INLETS 120V

*Note: Add GE-V1 or GE-V2 variable speed modules to control prices above and/or GE-AIR inlet modules as application requires.

E53-9775 GE-V1 ONE VARIABLE STAGE MODULE 10AMP
E53-9780 GE-V2 TWO VARIABLE STAGE MODULES 10AMP EACH
E53-9785 GE-AIR/1-120V ONE INLET 120V MODULE (NO DISPLAY)
E53-9790 GE-AIR/2-120V TWO INLETS 120V MODULE (NO DISPLAY)
E53-9792 GE-MO10-120V 0-10 VOLT MODULE (REQ’D FOR EACH CHIMNEY DAMPER)
E53-9715 GE-R4 FOUR TOGGLE OFF/ON, 2HP RELAY BOX
E53-5402 T15-WD ONE SPEED THERMOSTAT 10AMP. (SAFETY OVER-RIDE)

Note: Provide at least one safety T15-WD over-ride for GE-641, GE-642, and two safety over-rides for GE-644/646.

Genius Control System

PART # MODEL # DESCRIPTION
E53-9705/24 GE-641/IN1/24 KIT ONE RELAY, ONE INLET 24VOLT
E53-9725/24 GE-642/IN1/24 KIT TWO RELAYS, ONE INLET 24VOLT
E53-9785/24 GE-AIR/1/24V 24VOLT AIR INLET MODULE (GE641-646)
     
E53-4930 2004-10K 10″ TEMPERATURE PROBE (ADD AS REQUIRED)
E53-4934 2004-10K/30 30FT TEMPERATURE PROBE (ADD AS REQUIRED)
E53-4670 RH-3 HUMIDITY PROBE
E53-4677 CRH-3/MGCB RED WIRE HARNESS REQUIRED WITH RH-3

Genius “Core 100” Technology Controls

Features:
Quick key pads for grouping settings, 3/4″x2″ LCD screen, 30 day history, up to 4 inside probes, one outside probe, humidity probe option; use RH3 and red harness and potentiometer feed back (order extra probes as required).

PART # MODEL # DESCRIPTION
E53-9835 GE-25 2 Internal variable stages, 5 multi-purpose off/on relays for up to 5 additional cooling stages, up to 2 heating stages, 1 two level mist stage or 1 inlet using 2 relays with pot feed back, 1-10k probe included.
E53-9840 GE-28
NOTE: DISCONTINUED parts only avail.
2 Internal variable stages, 8 multi-purpose relays for up to 8 additional cooling stages, up to 4 heater stages 1 two level mist, 1 water meter input. 
E53-9846 AIRIN-1 Inlet board option for GE-28 only (1 inlet)
E53-9848 AIRIN-2 Inlet board option for GE-28 only (2 inlet)
E53-9849 MM-4 Memory stick for core 100 (to transfer settings from control to control)

Belimo Actuator Control For Chimney Dampers & Inlet Shutter

0-10v models can be operated using GE-6x or GE-425/430 controls.
Spring return can be operated by relays of all controls.

PART # MODEL # DESCRIPTION
**E57-8015 NMX120-SR BELIMO 120V        0-10V SIGNAL
E57-8011   BELIMO MOISTURE RESISTANT ENCLOSURE & MOUNTING BRKT (MOUNTS ON SIDE OF CHIMNEY MODULE)

** While Quantities Last

Genius GE-4x Series Control System

Easy to view (2-1/2″ x 1-3/4″) LCD screen
6 HOT key pads

4 variable stages, 6 amp c/w ability to boost 10 more amps by using GE-V1 or GE-V2 modules. NOTE: Two of the variable stages can be used as manual variable stages to run circulation fans. 10, 15 or 20 2HP relay contactors for up to 12 cool stages, 6 heat, 2 clocks c/w 6 off/on cycles, 1 mist and 6 inlets (NOTE: each inlet requires 2 relays).

Program features SolarWall Boost Logic, outdoor compensation, temperature and min speed curves, dehumidification logic, night set point, water counter (1), natural ventilation and tunnel logic to operate curtains and tunnel inlets by time mode or potentiometer feed back.

* Core 1000 technology

PART # MODEL # DESCRIPTION
E53-9850 GE-410R 4 VARIABLE STAGES, 10 OFF/ON RELAYS, 1 PROBE
E53-9860 GE-415R 4 VARIABLE STAGES, 15 OFF/ON RELAYS, 1 PROBE
E53-9870 GE-420R 4 VARIABLE STAGES, 20 OFF/ON RELAYS, 1 PROBE

Required Additional Items

PART # MODEL # DESCRIPTION
E53-9211 CM-128 CONFIGURATION CHIP (FOR UP LOADING & DOWN LOADING SETTINGS)
E53-4930 2004/10K PROBE (ADD UP TO 6 PER CONTROL)
E53-5402 T-15-WD SAFETY OVER-RIDE (3-4 RECOMMENDED)

Options

PART # MODEL # DESCRIPTION
E53-4670 RH-3 HUMIDITY PROBE
E53-4677   RED WIRE HARNESS – REQUIRED WITH RH-3
E53-9055 750JLPRS WATER METER C/W PULSE (3/4″ CONNECTION, 1 PER CONTROL)
E53-9830 X1202 PC COMMUNICATION BOARD GE-4X / AGRI-MANAGER
E53-9775 GE-V1 GE-V1 MODULE, 1 STAGE VARIABLE 10 AMP BOOSTER
E53-9780 GE-V2 GE-V2 MODULE, 2 STAGE 8 AMP BOOSTER PER STAGE

Genius Light Control

* Core 100 technology

Up to two dimming zones, 20 growth periods, 5 cycles per day, 3 stimulation cycles. Two out-puts of 1800 watts @ 120volt.**

GE-l2/LED specific for LED dimmable lights

PART # MODEL # DESCRIPTION
E53-5154 GE-L2/LED TWO OUTPUTS FOR 8 AMPS C/W OVER-RIDES SPECIFIC FOR LED LIGHTING
E53-5145 GE-L2 DIMMABLE LIGHT CONTROL C/W MANUAL OVER-RIDES

Voltage capacity can be boosted by using GE-V1 and GE-V2 modules or GE-V2/LED for GE-L2/LED control.

Genius GE-2x Series Control System

For Dual Ventilation/Natural Curtain Ventilation Systems

2-1/2″ x 1-3/4″ LCD screen – 6 HOT keys

2 Variable stages, 10,15 or 20 2hp off/on relays to operate up to 6 natural ventilation curtains or 4 natural curtains and 2 ceiling inlets in a dual ventilation system.

Note: Each curtain or inlet requires 2 relays. Up to 8 additional cool stages, 4 heat stages, 1 mist/soaking stage, 2 clock, 1 feeding clock with 6 off/on cycles. Toggle over-rides on all stages. 4 inside probes, 1 outside probe. Compensation requires static pressure GE-SP1/KIT.

Special logic for dual ventilation and curtain systems includes progressive timer curtain control and outdoor compensation to manage curtain control set points. Feed consumption history and alarm (current detection device and/or proximity sensor required) humidity over-ride logic. Water consumption history (meter required).

* Core 1000 technology

PART # MODEL # DESCRIPTION
E53-9910 GE-210R 2 VARIABLE STAGES, 10 OFF/ON RELAYS, 1 PROBE
E53-9915 GE-215R 2 VARIABLE STAGES, 15 OFF/ON RELAYS, 1 PROBE
E53-9920 GE-220R 2 VARIABLE STAGES, 20 OFF/ON RELAYS, 1 PROBE

Required Additional Items

PART # MODEL # DESCRIPTION
E53-9211 CM-128 CONFIGURATION CHIP (ADD ONE PER CONTROL)
E53-4930 2004/10K PROBE (ADD UP TO 4 PER CONTROL)
E53-5402 T-15-WD SAFETY OVER-RIDE (1-2 RECOMMENDED)

Options

PART # MODEL # DESCRIPTION
E53-4670 RH-3 HUMIDITY PROBE
E53-4677   RED WIRE HARNESS – REQUIRED WITH RH-3
E53-9055 750JLPRS WATER METER W/PULSE COUNT (3/4″ CONNECTION)
E53-9057 1000JLPS WATER METER W/PULSE COUNT (1″ CONNECTION)
E53-9830 X1202 PC COMMUNICATION BOARD GE-4X / AGRI-MANAGER
E53-9898A CSD-1A CURRENT DETECTOR (REQUIRED FOR FEED LOGIC)
E53-9895 GE-SP1/KIT STATIC PRESSURE PROBE

Call for other options such as adding 2 variable stages, GE boosters and logic features.

Genius Feed Bin Monitoring System

An easy and effective way to manage feed bin inventory levels & feed consumption rates. This system consists of a master control GE-BIN4, which monitors up to 4 feed bins. The SB15K shear beam requires bin to be lifted by approximately 8-10″.

* Core 2000 technology

PART # MODEL # DESCRIPTION
E53-9605 GE-BIN4 MASTER CONTROL (MONITOR UP TO 4 FEED BINS)
E53-9610SB GE-FBT-1SB FEED TRANSMITTER (1 PER BIN) FOR SB15K
E53-9611 GE-LIM (1 PER BIN) LIGHTNING ISOLATOR MODULE WITH TRANSFORMER
E53-9615 SB15K/KIT SHEAR BEAM KIT W/SUPPORT -1 PER LEG (6 MAX/BIN) MAX LOAD 7.5 METRIC TON
E53-9618 DSB-22K/KIT 10MT LOAD CELL C/W SUPPORT – 1 PER LEG
E53-9898A CSD-1A 1-4 CURRENT DETECTOR (1 PER AUGER)

NOTE: Bins must have a max of 6 legs.

Genius GE-4xxLSR Series Control System

Genius GE-415LSR and GE-420LSR Controls

Large LCD screen (4-1/2″ x 2-1/2″)
6 HOT key pads

4 variable stages, 6amp c/w ability to boost 10 more amps by using GE-V1 or GE-V2 modules. Up to 11 inside probes and 1 outside. 15 or 20 2HP relay contactors for up to 20 cool stages, 12 heat, 8 clocks with 6 off/on cycles, 1 mist expandable to 6 for a total of 8 adding x1200 input board, 1 water input and 8 inlets (NOTE: each inlet requires 2 relays). Up to 6 feed relays with 12 off/on cycles with optional current detection for alarm and feed history. Up to 8 waterflush relay options.

Optional 0-10V board allows control of up to 2 chimney dampers using Belimo or any other 0-10V actuator, frequency drives or light slaves. Option light module GE-V4/S-4 for control of dusk to dawn light programs (designed for fluorescents and incandescents) Off/On toggle switches on all stages. Program features SolarWall Boost Logic, outdoor compensation, dehumidification logic, temperature and min speed curves, misting restriction times, night set point, water counter, natural ventilation, dual ventilation, tunnel logic to operate curtains and tunnel inlets. Static pressure compensation requires GE-SP1/KIT.

Two light programs, Core 2000 Technology.

PART # MODEL # DESCRIPTION
E53-9865 GE-415 LSR 4 VARIABLE, 15 OFF/ON, 1 PROBE INCLUDED
E53-9875 GE-420 LSR 4 VARIABLE, 20 OFF/ON, 1 PROBE INCLUDED

Required Additional Items

PART # MODEL # DESCRIPTION
E53-4930 2004/10K  PROBE (ADD UP TO 11 PER CONTROL)
E53-5402 T-15-WD SAFETY OVER-RIDE (3-4 RECOMMENDED)
E53-9522 CM-512M CONFIGURATION CHIP (FOR UP LOADING & DOWN LOADING SETTINGS)

Options

PART # MODEL # DESCRIPTION
E53-4670 RH-3 HUMIDITY PROBE
E53-4677   RED WIRE HARNESS REQUIRED WITH RH-3 
E53-9055 750JLPRS WATER METER W/PULSE COUNT (3/4″ CONNECTION)
E53-9057 1000JLPS WATER METER W/PULSE COUNT (1″ CONNECTION)
E53-9287 GE-V4/S4 LIGHT MODULE – 4 OUTPUTS 1800 WATTS EA. W/ MAN OVER-RIDE (NOT LIKELY TO WORK SATISFACTORY WITH NEW LED LIGHTING)
E53-9878 X1201/640ER 0-10V 2 OUTPUTS BOARD (FOR BELIMO ACTUATORS, LIGHTS)
E53-9830 X1202/640ER PC COMMUNICATION BOARD
E53-9775 GE-V1 GE-V1 MODULE – 1 STAGE 10AMP BOOSTER
E53-9780 GE-V2 GE-V2 MODULE – 2 STAGE 10AMP BOOSTER
E53-9895 GE-SP1/KIT STATIC PRESSURE PROBE
E53-9898A CSD-1A CURRENT DETECTION (FOR FEED LOGIC) REQ 1 PER FEED RELAY
E53-9827 X1200/INPUT 9 INPUT BOARD (ADDS 7 WATER INPUTS)

Genius GE-425LSR and GE-430LSR Controls

Large LCD screen (4-1/2″ x 2-1/2″)
12 HOT key pads

  • 4 variable stages, 6amp c/w ability to boost 10 more amps by using GE-V1 or GE-V2 modules. 1 outside probe, 11 inside temp. probes 25 or 30 2HP relay contactors for up to 24 cool stages, 12 heat, 8 clocks, 4 mist and 8 inlets (NOTE: each inlet requires 2 relays).
  • Up to 6 feed relays with 12 off/on cycles with optional current detection for alarm and feed history (effective June 2012).
  • One water counter input. Expandable to 6 for total of 8 adding x1200 input board.
  • Optional 15 or 20 relay slave modules to maximize cool stages, heater stages and inlets to a maximum of 16.
  • Optional 0-10V board allows control of up to 2 chimney dampers using Belimo or any other 0-10V actuator, frequency drives, light slaves.
  • Optional light module GE-V4/S-4 for control of dusk to dawn light programs (designed for fluorescents and incandescents).
  • Off/On toggle switches on all stages. Program features SolarWall Boost Logic, outdoor compensation, dehumidification logic, temperature and min. speed curves, misting restriction times, night set point, natural ventilation and tunnel logic to operate curtains and tunnel inlets. Static pressure compensation requires GE-SP1/KIT.
  • Two light programs.
PART # MODEL # DESCRIPTION
E53-9880 GE-430LSR 4 VARIABLE, 30 OFF/ON, 1 PROBE INCLUDED
E53-9885 GE-425LSR 4 VARIABLE, 25 OFF/ON, 1 PROBE INCLUDED
E53-9930 GE-ST30LSER 30 OFF/ON RELAYS, 1 PROBE INCLUDED
E53-9925 GE-ST25LSER 25 OFF/ON RELAYS, 1 PROBE INCLUDED

Required Additional Items

PART # MODEL # DESCRIPTION
E53-4930 2004/10K  PROBE (ADD UP TO 11 PER CONTROL)
E53-5402 T-15-WD SAFETY OVER-RIDE (4-6 RECOMMENDED)
E53-9522 CM-512M CONFIGURATION CHIP (FOR UP LOADING & DOWN LOADING SETTINGS)

Options

PART # MODEL # DESCRIPTION
E53-9881 GE-SL15 15 RELAY MODULE, 8 POT BOARD INCLUDED
E53-9882 GE-SL20 20 RELAY MODULE, 8 POT BOARD INCLUDED
E53-4670 RH-3 HUMIDITY PROBE
E53-4677   RED WIRE HARNESS REQUIRED WITH RH-3 
E53-9055 750JLPRS WATER METER /W PULSE (3/4″ CONNECTION, UP TO 5 POSSIBLE)
E53-9057 1000JLPS WATER METER W/PULSE COUNT (1″ CONNECTION)
E53-9287 GE-V4/S4 LIGHT MODULE – 4 OUTPUTS 1800 WATTS EA. W/ MAN OVER-RIDE (NOT LIKELY TO WORK SATISFACTORY WITH NEW LED LIGHTING)
E53-9270 GE-V2/LED LED LIGHT MODULE, 2 OUTPUTS OF 8 AMPS EACH C/W MANUAL OVER-RIDES. OPERATES MOST DIMMABLE LED LIGHTS
E53-9878 X1201/640ER 0-10V 2 OUTPUTS BOARD (FOR BELIMO)
E53-9775 GE-V1 GE-V1 MODULE – 1 STAGE 10AMP BOOSTER
E53-9780 GE-V2 GE-V2 MODULE – 2 STAGE 10AMP BOOSTER
E53-9898A CSD-1A CSD-1 CURRENT DETECTION (FOR FEED LOGIC) 1 PER RELAY REQ’D
E53-9895 GE-SP1/KIT STATIC PRESSURE PROBE C/W ADAPTOR
E53-9827 X1200/INPUT 9 INPUT BOARD (ADDS 7 WATER INPUTS)

Genius GE-Nutri - Multi Program Feed Control System

  • Can now manage 5 program types: multi-feed, feed auger, chain auger, feed auger drop and chain feeder drop
  • Can operate up to 4 actuators c/w potentiometer
  • Up to 4 bins 6 cycle times per day
  • Feed usage history possible using current sensors on each bin
  • Can be connected to FarmQuest management system for remote control using the internet
PART # MODEL # DESCRIPTION
E53-4335 GE-NUTRI GE-NUTRI FEED CONTROL
E53-9898A CSD-1A ADJUSTABLE CURRENT SENSORS (UP TO 4)
E53-9715 GE-R4 4 TOGGLE OFF/ON 2HP RELAY BOX (RECOMMENDED)
E53-3043 X1314/R4 RELAY BOARD WITH 4 RELAYS

*Core 2000 technology

Use RF-IN2 and web-gate for FarmQuest system. 

Genius Parts

GENIUS 6X CONTROL SYSTEM PARTS

PART # DESCRIPTION
E53-9701 X1222/GE GE-64X TOP BOARD ONLY GE(1,2,4,6)
E53-9702 X1238/GE641 GE-641 BOTTOM BOARD ONLY
E53-9722 X1238/GE642 GE-642 BOTTOM BOARD ONLY
E53-9742 X1237/GE644 GE-644 BOTTOM BOARD ONLY
E53-9762 X1237/GE646 GE-646 BOTTOM BOARD ONLY
E53-9824 X1210 M-CORE 1000 PROCESSOR BOARD GE 6X/4X
E53-9707 X1239/IN1 IN1/120 120V ONE INLET BOARD -GE-641-646
E53-9712 X1239/IN2 IN2/120 120V TWO INLET BOARD-GE-641-646
E53-9708/24 X1240/IN/24 IN1/24 24VOLT & TRANSFORMER-GE-641-646
E53-9707/24 X1218/IN1/24 24 VOLT INLET BOARD GE-641-646
E53-9787/24 X1220/IN1/24 24 VOLT INLET BOARD GE AIR MODULE
E53-9795 P-8388 24 VOLT TRANSFORMER
E53-9776 X1243/GEV1 GE-V1 BOTTOM BOARD ONLY – GE-V1 MODULE
E53-9781 X1243/GEV2 GE-V2 BOTTOM BOARD ONLY – GE-V2 MODULE

GENIUS 4X, 420-LS, 430-LS, AGRI MANAGER PARTS

PART # DESCRIPTION
E53-9820KIT X1184/1640ERKIT  – 5 RELAY BOARD 
E53-9828KIT X1192/1640ERKIT –  5 TOGGLE BOARD 
E53-3044 X1206/4 TOGGLE BOARD GE-4X/GE-430/AGRM
E53-9829/2 X1206/2 TOGGLE BOARD 2VAR GE-2X
E53-9821 X1204 2 VARIABLE BOARD GE-4X/GE430/AGRM
E53-9822 X1205/8 POT BOARD GE-4X/GE-430/AGRM
E53-9823 X1224 MASTER MAIN BOARD GE-4X
E53-9824 X1210 M-CORE 1000 PROCESSOR BOARD GE-4X/6X
E53-9825  X1222/GE2211  DISPLAY BOARD GE-4X
E53-9826 X1416 OUTPUT SLIM BOARD GE-4X/GENIUS-430/IT
E53-9827 X1200 9 INPUT BOARD (PROBE/HUM) GE-4X/AGRM 
E53-9834 X1199 SENSOR & COMM. BOARD GE-430/AGRM
E53-9832 LPS63B 12 VOLT 60W POWER SUPPLY GE4X,43O/AGRM
E53-9876 X1224 MAIN BOARD 420-LS
E53-9877 X1285 DISPLAY/INTERFACE 420-LS
E53-9891 X1323 MAIN BOARD ONLY GE-430
E53-9892 X1211 CORE 2000 MICROPROCESSOR BOARD GE-430/AGRM
E53-9890 X1323/LSR KIT (MAIN BOARD C/W MICROPROCESSOR) GE-430
E53-9893 X1226 MASTER MAIN BOARD ONLY / AGRM 
E53-9894 X1228 DISPLAY BOARD / AGRM
E53-9833 PLASTIC CAPS FOR FRONT COVER
E53-4034 216-315 FUSE 3.15 AMP FOR 12VOLT POWER SUPPLY LPS63B
E53-9883 1333/SLRL MINI SLIM BOARD -RELAY MODULE
E53-9884 X1322 DISPLAY BOARD FOR GENIUS 430

GENIUS GE-25,GE-28 PARTS

PART # DESCRIPTION
E53-9837 X1281/GE-25 TOP BOARD ONLY 
E53-9838 3281/GE-25 TOP BOARD AND HOUSING
E53-9839 X1282/GE-25 BOTTOM BOARD ONLY
E53-9842 X1277/GE-28 TOP BOARD ONLY
E53-9844 X1278/GE-28 BOTTOM BOARD ONLY
E53-9845 X1279/VIN-2 GE-25/GE-28 VARIABLE BOARD ONLY 
E53-9847 X1255/C100 GE-25/GE-28 CORE 100 MICROPROCESSOR BOARD